LabVIEW 8.6 DSP Module (DSP设计):

LabVIEW8.6DSPModule(DSP设计):NILabVIEW8.6D

  • 80分
  • 浏览次数:195
  • 行业分类:机械设备
软件大小: 未知
软件授权:免费
上传时间:2022-03-19

LabVIEW 8.6 DSP Module (DSP设计):
NI LabVIEW 8.6 DSP Module 。DSP 模块是一个全功能的可视化 DSP 设计工具,基于LabVIEW可视化程序环境。可以建立实时的应用程序。与LabView集成,功能相当强大,是DSP开发的新思路!

NI LabVIEW 8.6 DSP Module 这是NI公司近期最新发行的一款软件,为LabVIEW 8.6 Embedded Edition。

//安装该软件所需求软件为:LabVIEW 8.6,

LabVIEW 8.6 DSP Module 特性包括:

易用的可视化程序环境

直接获取DSP目标的数字的和类似的I/O线路

全面支持 Express VIs 获得更快的编码环境

不必重写代码可以在支持的DSP目标之间切换

开发独立的DSP应用程序

数字过滤的无缝结合

Known Issues
Larger data types, such as double-precision numerics, might be coerced to a smaller data type, such as a single-precision numeric, without warning or error when you target a DSP depending on the capabilities of the processor.
Smaller data types, such as 8-bit integers, might be converted to larger data types, such as 32-bit integers, without warning or error when you target a DSP depending on the capabilities of the processor.
The square root of a negative number returns zero.
The Natural Logarithm function and the Logarithm Base 10 function return 0 rather than NaN if x is a negative number.
Infinity does not have a special bit encoding on DSP targets and so, +/- Infinity is mapped to the respective maximum and minimum value for the data type.
On the LabVIEW DSP Module Status Monitor window, the memory usage cannot exceed approximately 97.5% due to memory fragmentation on the DSP.
When you place an Express VI on a block diagram, the configuration dialog box does not automatically display. Double-click the Express VI on the block diagram to open the configuration dialog box.
Unsigned integers are not supported when you are targeted to a DSP.
Scalar uninitialized shift registers start with their default value each time you run a DSP VI with a DSP execution target, even if no edits are made to the VI. This behavior differs from LabVIEW for Windows. When you use the DSP Module with the LabVIEW for Windows execution target, the behavior is the same as LabVIEW for Windows. The DSP Module does not support array uninitialized shift registers.
If you put values in local variables in front panel controls, these values are not updated on the front panel. To see the value, create an indicator on the wire.
The Compare Aggregates mode for Comparison functions return incorrect results when targeted to the DSP.
SPEEDY-33 If you are using the SPEEDY-33 Robot Daughter Module with the SPEEDY-33 execution target, you cannot use the Digital Input, Digital Output, Digital Bank Input, or Digital Bank Output Elemental I/O Nodes because they share the same hardware resources.
6713 DSK You must run a VI before you can download any VI to flash memory. The VI you run does not have to be the same VI you want to download to Flash memory.


Unsupported Features
Probes, breakpoints, and execution highlighting
Feedback Nodes with the initialization terminal
Parallel execution
Global variables
Expandable terminals on array operations and other functions
The Elemental I/O templates in the New dialog box
You cannot have multiple VIs running at the same time

下载地址
  • 登录后查看下载地址!
相关下载

Ta的简介

   
介绍:无
14729 发表文章 1 粉丝 0 关注

公众号

小程序

在线客服